Echo LSIS Control
Standard Product Guide V1.0 02/2020
Manual Motor Starters Meta-MEC Contactors & Overload Relays MC/TOR STANDARD PRODUCT GUIDE
Contents
Manual Motor Starters
2 4 5 6 6 7 7 8
Quick selection table ... IEC rating High breaking type Accessories
IEC performance data (Motor protection)
Manual Motor Controller (UL508) Type '2' coordination according to IEC 947-4-1 Dimensions Manual motor controller (UL 508, CSA C22.2 as Manual motor controllers)
Contactors & Overload Relays
12 14 16 17 21 24 25 26 27 28 29 33
Table of specifications
Type numbering system Control coil characteristics 3-pole Contactors
Accessories
Overload relays Overload relay specifications Accessories for overload relays Overload relay ordering types
Ready for IE3
Dimensions Certifications
1
Manual Motor Starters Product Selection Guide Quick selection table ... IEC rating
Frame
32AF
MMS-63H High breaking Rotary 63AF
Type
Current adjustable type Breaking capacity
MMS-32H High breaking Rotary
Handle type
Number of poles
3 Up to 690V
3 Up to 690V 50/60 Hz 1,000V 8kV Cat. A AC 3
Rated operational voltage (Ue)
Rated frequency
50/60 Hz
Rated insulation voltage (Ui) Rated impulse voltage (Uimp)
690V
6kV
Utilization category
IEC 60 947-2 (Breaker)
Cat. A
IEC 60 947-4 (Motor starter)
AC 3
Mechanical endurance (Operating) Electrical endurance (Cycles)
100,000 100,000
50,000 25,000 25
Max operating frequency per hour (Ope./h) Temperature compensation (Operation)
25
-20 ~ +60°C 13 X Іe max.
-20 ~ +60°C 13 X Іe max.
Instantaneous short circuit release Overload protection
O O X O
O O X O 1,000
Phase failure function Trip indicating function
Test function
Weight (g)
360
Rated
220V 415V 460V 525V 690V 240V 230V Іcs 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 400V 440V 500V 600V 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 8 8 100 100 100 100 100 100 100 100 8 8 100 100 100 100 100 100 100 100 6 6 100 100 100 100 50 38 50 38 6 6 100 100 100 100 50 38 50 38 6 6 100 100 100 100 50 38 42 32 100 100 50 38 20 15 10 8 4 4 100 100 50 38 20 15 10 8 4 4 100 100 50 38 20 15 10 8 4 4 100 100 50 38 20 15 10 8 4 4 100 100 40 30 15 11 8 6 3 3 6 6 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Іcu Іcs 100 100 Іcu 100 Іcs 100 Іcu 100 Іcs 100 Іcu 100 Іcs 100 Іcu 100
220V 415V 460V 525V 690V 240V 230V Іcu Іcs - - Іcu - Іcs - Іcu - Іcs - Іcu - Іcs - Іcu - Іcs - - - - - - - - - - - 400V 440V 500V 600V
Rated operational Thermal release
breaking capacity
Adjustment range (A)
current (Ie)
(kA)
0.1~0.16 0.16~0.25 0.25~0.4 0.4~0.63
0.16 0.25 0.4 0.63 1
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - -
0.63~1 1~1.6 1.6~2.5 2.5~4
1.6 2.5
4 6 8
4~6 5~8
- 100 100 100 100 50 38 50 38 6 5 100 100 100 100 50 38 42 32 100 100 50 50 50 38 12 9 5 5 100 100 50 50 50 38 12 9 5 5 100 100 50 50 35 27 12 9 5 5 100 100 50 50 35 27 10 8 5 5 100 100 50 50 35 27 10 8 5 5 6 5 100 100 50 50 35 27 10 8 5 5 100 100 50 50 35 27 10 8 5 5 75 50 35 27 25 19 6 5 3 3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
6~10 9~13
10 13 17 22 26 32 40 50 63 65 75 90 100
11~17 14~22 18~26 22~32 28~40 34~50 45~63 47~65 55~75 70~90 80~100
2
Manual Motor Starters Product Selection Guide Quick selection table ... IEC rating
Frame
100AF
Type
Current adjustable type Breaking capacity
MMS-100H High breaking Rotary
Handle type
Number of poles
3 Up to 690V
Rated operational voltage (Ue)
Rated frequency
50/60 Hz
Rated insulation voltage (Ui) Rated impulse voltage (Uimp)
1,000V
8kV
Utilization category
IEC 60 947-2 (Breaker)
Cat. A
IEC 60 947-4 (Motor starter)
AC 3
Mechanical endurance (Operating) Electrical endurance (Cycles)
50,000 25,000
Max operating frequency per hour (Ope./h) Temperature compensation (Operation)
25
-20 ~ +60°C 13 X Іe max.
Instantaneous short circuit release Overload protection
O O O O
Phase failure function Trip indicating function
Test function
Weight (g)
2,200
Rated
220V 415V 460V 525V 690V 240V 230V Іcu Іcs Іcu Іcs Іcu Іcs Іcu Іcs Іcu Іcs 400V 440V 500V 600V
Rated operational Thermal release
breaking capacity
Adjustment range (A)
current (Ie)
(kA)
0.1~0.16 0.16~0.25 0.25~0.4 0.4~0.63 0.63~1 1~1.6 1.6~2.5 2.5~4
- - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
0.16 0.25 0.4 0.63 1
1.6 2.5
4 6 8
4~6 5~8
6~10 9~13
10 13 17 22 26 32 40 50 63 65 75 90 100
- - 100 100 100 100 50 38 35 27 12 9 100 100 100 50 50 38 35 27 12 9 100 100 100 50 50 38 35 27 12 9 100 100 100 50 50 38 25 19 12 9 100 100 100 50 50 38 20 15 12 9 - - 100 100 100 50 50 38 15 11 10 8 100 100 100 50 50 38 15 11 8 6 - - - - - - - - - - 100 100 75 50 50 38 12 9 6 6 100 100 75 50 50 38 12 9 6 6 100 100 75 50 50 38 12 9 6 6
11~17 14~22 18~26 22~32 28~40 34~50 45~63 47~65 55~75 70~90 80~100
3
Manual Motor Starters Product Selection Guide
High breaking type
∙ Adjustable thermal release ∙ Magnetic release 13 Ie max. ∙ Trip class 10 ∙ Protective function ∙ Phase-failure protection - phase-failure - short circuit - overload
MMS-32H MMS-63H MMS-100H
Rated
Thermal
Magnetic
Switching of 3 phase AC motors, AC-2, AC-3
400/415V
operational
release release Adjustment Operating
3-phase [kW] (50/60hz)
3-phase [HP] (60Hz)
current
Type
Іcu Іcs
range
current
230V
400V
690V
230V
460V
575V
Іe
[kA]
[kA]
17 22 32 40 50 65 75 [A]
[A]
[A]
11...17 14...22 22...32 28~40 34~50 47~65 55~75 80~100
221 286 416 520 650 845 975
4 4
7.5 7.5
11 15 22 30 45 55 63 90
5
10 15 20 30 40 50 60 75
15 20 30 40 50 60 75
50 50 50 40 50 35 75 75
38 38 38 30 50 27 50 50
7½
MMS-32H
7.5 7.5
15
10 15 15 20 25 40
18.5
11 15 22 30
22 30 37 45
MMS-63H
MMS-100H
100
1300
100
4
Manual Motor Starters Product Selection Guide Accessories (Electrical Auxiliaries)
Enclosure Case cover of MMS enclosure is specifically designed with dust-proof and corrosive-proof structure. Therefore, it is the optimum product to use in dusty areas such as cement plants, cotton mills as well as in the presence of corrosive gas or liquid (excl. explosive, flammable gas) such as fertilizer, refinery, and plating plant.
●
∙ Application Model: MMS-32H/HI ∙ Operation temp. : -20 ~ +60°C ∙ CE and UL certified ∙ Degree of protection : IP65 ∙ Material of insulation :Plastic(ABS)
Type
Application MMS
Remarks
EPH-32
MMS-32H
Surface mount
●
Direct adaptor and Mounting unit Direct adaptor , DA Direct adaptor is used to connect MMS directly with a contactor Mounting unit , MU This device is attached module to connect joined MMS with a contactor ∙ Application Model : MMS+ Susol contactor(MC-9~95), Mini contactor Direct adaptor Mounting Combined devices
Applying Contactor
unit
Frame Name
MMS-32H + MC-9b~22b
DA-22 DA-22HA
Metasol MC
MU-45
Susol, Metasol MC
DA-32HA
MMS-32H + MC-9~32(32a, 40a)
DA-32
DA-63 DA-63A
MU-55
MMS-63AF + MC-35~63 (50a, 65a)
Susol, Metasol MC (Lug Type Only)
DA-95 DA-95A
MU-70
MMS-100AF + MC-65~95 (75a, 85a, 100a)
MMS-100
MMS-63
MMS-32
MC-95 Note) MMS and Contactor connected with Direct adaptor. MC-63 MC-32
5
Manual Motor Starters Technical Information IEC performance data (Motor protection)
High breaking type MMS 32H Rated operational current Іe ●
MMS 63H ● 50 65
MMS 100H ● 75 100
[A]
17
22 32 40
Switching of standard three-phase motors AC-2, AC-3 230/240V
4 7.5 7.5 7.5 7.5 15 1.8 11 11 18.5 22 11 15 22 30
11 15 22 30 30 37 45 55
22 30 37 45 45 63 63 90
[kW] 3.7/4
400/415V
[kW] [kW] [kW]
500V 690V
Back-up fuses gG, gL,, only if Іcc>Іcu ( * = No back up fuse required) 230/240V
* * 100 125 125 160 80 100 100 125 80 80 80 100 63 63 63 80 100 100 100 100 50 50 50 40 20 20 20 15 10 10 10 8 4 4 4 3 * * 100 100 100 100 38 38 38 30 15 15 15 11 8 8 8 6 4 4 4 3
* * 160 160 125 160 100 100 80 80 100 75 50 35 35 25 10 6 5 3 100 50 50 27 27 19 8 5 5 3
* *
*
[A] [A] [A]
* 200 200 160 160 125 160 100 100 75 75 50 50 12 12 6 6
400/415V 440/460V
V005
]A[ ]A[
V096 Ultimate short-circuit breaking capacity Іcu 230/240V
[kA] [kA] [kA] [kA] [kA] [kA] [kA] [kA] [kA] [kA]
400/415V 440/460V
500V 690V
Rated service short-circuit breaking capacity Іcs 230/240V
100 100 50 50 38 38
400/415V 440/460V
9 9 6 6
500V 690V
Note) * = Short circuit proof up to 50 or 100kA. No back up fuse required.
Manual motor controller (UL 508, CSA C22.2 as Manual motor controllers)
Combination Motor Controller - Group lnstallation - Type E starter
MMS 63H ● 50 65
MMS 100H ● 75 100
MMS 32H ●
Rated operational current Іe Max. short-circuit current 240V
[A]
17
22 32 40
100 30 10
100 30 10
100 30 10
100 50 10
100 50 10
[kA] [kA] [kA]
100 30 10
100 50 10
100 50 10
480V 600V
Motor load
In case of 1-phase use in series as shown below
1 1.5 2 3 3 3 5 7.5 3 5 7.5 10 5 7.5 10 10 10 15 20 30 15 20 30 30
1 Phase 115V
[HP] [HP] [HP] [HP] [HP] [HP]
3 5 10 10 20 20 20 20 40 40 60 60
5 10 15 20 20 30 25 30 50 75 60 100
230V
3 Phase 200V
230V 460V 575V
Maximum rated current
500 500 500 500
[A]
600 600
1000 1000
of fuse or breaker
6
Manual Motor Starters Technical Information Manual Motor Controller (UL508)
MMS 32H ●
MMS 63H ● 50 65
MMS 100H ● 75 100
Rated operational current Іe Max. short-circuit current 240V
[A]
17 22 32 40
100 30 10
100 30 10
100 30 10
100 50 10
100 50 10
[kA] [kA] [kA] [HP] [HP] [HP] [HP] [HP] [HP]
100 30 10
100 50 10
100 50 10
480V 600V
Motor load
In case of 1-phase use in series as shown below
3 7.5
2 5 7.5
1.5 3 5 7.5
5 10 20 20 40 60
10 20 30 30 75
1 Phase 115V
1 3 3 5
5 10 20 20 40 60
5 15 20 25 50 60
230V
10 10 30 30
3 Phase 200V
10 20 30
230V 460V 575V
15 20 80 80
10 15 60 60
100 400 400
150 150
125 125
250 250
Max. fuse size
[A] [A]
250 250
350 350
Max. breaker size
Type '2' coordination according to IEC 947-4-1
●
Short-circuit current Iq = 50kA Voltage : 400/415V, 50/60Hz
Manual motor starter
Standard motors AC-3
Thermal overload Magnetic release
Contactor
at 400/415V
Circuit breaker
release
response current
setting range
1500rpm
[kW] 7.5
[A]
Type
[A]
[A]
Type
[A]
15.5
MMS-32H 17A MMS-32H 22A MMS-32H 32A MMS-63H 40A MMS-100S 75A MMS-100S 100A
11~17 14~22 22~32 28~40 55~75
221 286 416 520 975
GMC-22 GMC-32 GMC-32 GMC-50 GMC-75 GMC-85
22 32 32 50 75 85
10 15
20 29 35 67 80
18.5
37 45
80~100
1300
Definition type '2' coordination according to IEC 947-4-1 : The contactor or the starter must not endanger persons or systems in the event of a short-circuit. The contactor or the starter must be suitable for further use. No damage to the overload relay or other parts may occur with the exception of welding of the contactor or starter contacts provided that these can be easily separated without significant deformation (such as with a screwdriver). • • •
7
Manual Motor Starters Technical Information Dimension
●
MMS 32H
[ mm ]
0.36kg
(+45mm)
1) Side auxiliary switch 2) Side magnetic trip alarm switch 3) Side shunt release or Side undervoltage release 4) Front auxiliary switch 5) Handle lock in OFF position (Ø 5mm) 6) Push-in Lugs for screw mounting 7) 35mm standard mounting rail acc. to EN 50 022
MMS-32H/HI+PB-32(2,3 Terminal) PB-322(2 Terminal), PB-323(3 Terminal) PB-324(4 Terminal), PB-325(5 Terminal)
8
Manual Motor Starters Technical Information Dimension
●
MMS 63H
[ mm ]
1kg
1) Side auxiliary switch 2) Side magnetic trip alarm switch 3) Side shunt release or Side undervoltage release 4) Front auxiliary switch 5) Handle lock in OFF position (Ø 5mm) 6) 35mm standard mounting rail acc. to EN 50 022
MMS-63S/H/HI+PB-63(2,3 Terminal) PB-632(2 Terminal), PB-633(3 Terminal)
9
Manual Motor Starters Technical Information Dimension
●
MMS 100H
[ mm ]
2.2kg
1) Side auxiliary switch 2) Side magnetic trip alarm switch 3) Side shunt release or Side undervoltage release 4) Front auxiliary switch 5) Handle lock in OFF position (Ø 5mm) 6) 35mm standard mounting rail acc. to EN 50 022 7) 75mm standard mounting rail acc. to EN 50 023 8) 4mm hexagon socket screw
10
Manual Motor Starters Technical Information Dimension
●
Enclosure for MMS 32H
[ mm ]
14
11
Table of specifications
MC type Magnetic Contactors
22AF
40AF
Frame size Type
MC-9b
MC-12b MC-18b MC-22b
MC-32a
MC-40a
●
●
●
●
●
●
screws clamp terminals Lug clamp terminals
Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency Rarted impulse withstand voltage, Uimp Maximum operating rate in operating cycles per hour (AC3) Durability Mechanical Electrical Current AC-1, Thermal current A and AC-3 200/240V kW power A 380/440V kW A 500/550V kW A 690V kW A 1000V kW A Rated Short-time 1s A withstand current 10s A (IEC 60947) 30s A 1min A 3min A 10min A ≥15min A UL rating Continuous current A (50/60Hz) Single 110-120V HP phase 220-240V HP 200-208V HP Three 220-240V HP phase 440-480V HP 550-600V HP NEMA size Size AC Weight kg and control Size(W x H x D) mm weight DC Weight kg control Size(W x H x D) mm Auxiliary (standard) Auxiliary
3pole 690V 690V 50/60Hz 6kV 1800 operations per hour
3pole 1000V 1000V 50/60Hz 8kV 1800 operations per hour
15 mil. operations 2.5 mil. operations
12 mi. operations 2 mil. operations
25 2.5 11
27 3.5 13 5.5 12 7.5 12 7.5
32 4.5 18 7.5 18 7.5 13 7.5
45 5.5 22 11 22 15 20 15 18
55 7.5 32 15 32
60 11 40 40 22 32 22 23 22 17
4 9 4 7 4 6
18.5
18.5
28
18.5
9
9
20 22 17
- -
- -
- -
- -
250 110
280 120
300 154 100
400 186 130
600 260 160 100
700 300 190 120
70 61 45 30 26 25
80 61 50 30 28 25
84 60 40 30 40
90 60 40 45 40
70 55 50 50
80 65 60 60
0.5 1.5
0.75
1 3
2 3
2 5
3
2 3 5
7.5 15 15 30 30
2 3 5
7.5 7.5 10 15
O6J O6J
7.5 10 20 25 1P
7.5 10
15 20
7.5 00
0
1
0.34 45 x 73.5 x 87.4 0.41 45 x73.5 x103.6
0.55 69 x 83 x 90 0.77 69 x 83 x 117.1
1a1b UA-1 UA-2, UA-4
2a2b UA-1 UA-2, UA-4
Side mount Front mount
Note) Minimum conduct current of Auxiliary contactor is DC 17V 5mA.
Thermal Overload Relays MT type
MT-32/� ●
MT-32/� ●
Type
screws clamp terminals Lug clamp terminals
690V 690V 6kV
690V 690V 6kV
Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Trip class Setting range Size and weight Weight
10A, 20 0.1~40A 0.17
10A, 20 0.1~40A 0.17
kg
45 x 75 x 90
45 x 75 x 90
Size(W x H x D) mm
* The safety cover of magnetic contactor and thermal overload relay is optional.
12
Table of specifications
MC type Magnetic Contactors
65AF
100AF MC-85a
Frame size Type
MC-100a ●
MC-50a
MC-65a
MC-75a
● ●
● ●
● ●
● ●
screws clamp terminals Lug clamp terminals
●
Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency Rarted impulse withstand voltage, Uimp Maximum operating rate in operating cycles per hour (AC3) Durability Mechanical Electrical Current AC-1, Thermal current A and AC-3 200/240V kW power A 380/440V kW A 500/550V kW A 690V kW A 1000V kW A Rated Short-time 1s A withstand current 10s A (IEC 60947) 30s A 1min A 3min A 10min A ≥15min A UL rating Continuous current A (50/60Hz) Single 110-120V HP phase 220-240V HP 200-208V HP Three 220-240V HP phase 440-480V HP 550-600V HP NEMA size Size AC Weight kg and control Size(W x H x D) mm weight DC Weight kg control Size(W x H x D) mm Auxiliary (standard) Auxiliary
3pole 1000V 1000V 50/60Hz 8kV 1200 operations per hour
3pole 1000V 1000V 50/60Hz 8kV 1200 operations per hour 12 mi. operations
12 mi. operations 2 mil. operations
1 mil. operations
2 mil. operations
160 30 105 55 105
100
115 18.5
125
135
15 55 22 50 30 43 30 28 30 23
22 75 37 75 37 64 37 42 37 28
25 85 45 85 45 75 45 45 37 28
65 30 65 33 60 33 35 30 23
55 85 55 65 37 28 1320
1000
1050
1100
1200
900 500 400 270 180 160 160
550 330 250 150
700 380 270 200 120
750 400 300 220 140 114 110
800 450 350 270 170 150 135 7.5
90 87 70 10 20 25 40 50 3
96
100
10 20 30 40 75 75
5
5
15 25 30 50 60
15 25 30 50 60
15 30 40 60 75
3
1.05 79 x 106 x 119 1.3 79 x 106 x 146.4
1.93 94 x 140 x 135.8 2.8 94 x 140 x 172.3
2a2b UA-1 UA-2, UA-4
2a2b UA-1 UA-2, UA-4
Side mount Front mount
Note) Minimum conduct current of Auxiliary contactor is DC 17V 5mA.
Thermal Overload Relays MT type
MT-63/� ●
MT-95/� ●
Type
screws clamp terminals Lug clamp terminals
●
●
690V 690V 6kV 10A, 20 4~65A 0.31/0.33
690V 690V 6kV
Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Trip class Setting range Size and weight Weight
10A, 20 7~100A 0.48/0.5
kg
55 x 81 x 100
70 x 97 x 110
Size(W x H x D) mm
* The safety cover of magnetic contactor and thermal overload relay is optional.
13
Type numbering system
Contactors
-
-
-
-
MC65A
40
22
K7
L
*note2)
Product (6A~2650A)
Main contactor
Auxiliary contact
Coil voltage
Terminal
MC6A MC-6a
00 None 11 Normal 1NO Normal 1NC 22 Normal 2NO Normal 2NC 11L LowCurrent1NOLowCurrent1NC 22L LowCurrent2NOLowCurrent2NC 11H Hoist 1NO Normal 1NC 22H Hoist 2NO Normal 2NC
30 3NO 0NC 40 4NO 0NC 22 2NO 2NC
S Screw L Lug B Hex Bolt
See Coil Code Table
MC2650A MC-2650a MC9B MC-9b
MC22B MC-22b
ex)
- A :Metasol A Type - B :Metasol B Type
MC65A-30-00-Q7-S-E MC75A-30-22-H7-L-E MC185A-30-22-FV-B-E MC85A-40-00-M7-S-E MC800A-40-22-EV-B-E
MC-65a AC380V 50/60Hz SCREW (Metasol) EXP MC-75a AC100V 50/60Hz LUG 2a2b (Metasol) EXP
MC-185a AC100-240V 50/60Hz, DC100-220V 2a2b (Metasol) EXP
MC-85a AC220V 50/60Hz 4P (Metasol) EXP MC-800a AC/DC200V 2a2b 4P (Metasol) EXP
*note2) 3pole S: Screw with Phillips head; Bare wire or fork terminal are accessible. (Applied model : MC6A to MC150A) L: Box Lug; Bare wire is accessible. (Applied model : MC50A to MC150A) B: Screw with Hex Bolt head; Ring terminal or fork terminal are accessible. (Applied model : MC185A to MC2650A) 4pole S: Scew with Phillips head; Bare wire or fork terminal are accessible. (Applied model : MC6A to MC85A) L: X B: Screw with Hex Bolt head; Ring terminal or fork terminal are accessible. (Applied model : MC100A to MC800A)
Thermal Overload Relay MT-12
Coil code table
-
3H
0.1
AC Control
Code
Coil Voltage
B7 E7 K7
24VAC 50/60Hz 48VAC 50/60Hz 120VAC 50/60Hz 220VAC 50/60Hz 230VAC 50/60Hz 240VAC 50/60Hz 208VAC 60Hz
Relay version
Relay setting current
Rated current
12 12AF 32 32AF 63 63AF 95 95AF
0.1
0.1A
Non-differential (3-heater)
3H
LB6 M7 P7 U7 W6
3K Differential 3D Class 20
800
800A
480VAC 60Hz
DC Control
800 800AF
Code
Coil Voltage
BD
24VDC
14
Type numbering system
Optional Accessories Auxiliary contact unit
Surge absorber
-
US
11
UA1
11
Contact composition
Product Composition
Voltage
Version
Varistor+RC Varistor+RC Varistor+RC
1 AC 24-48V 2 AC 100-125V 4 DC 24-48V
UA-1 Side mount
11 40 31 22 13 04
1NO+1NC
UA-2 Front mount(2P) UA-4 Front mount(4P) Note) UA-2: 2NO, 1NO1NC, 2NC UA-4: 4NO, 3NO1NC, 4NC 2NO2NC, 1NO3NC
4NO
3NO+1NC 2NO+2NC 1NO+3NC
4NC
Interlock unit
Wire kit for Interlocking
Separate mounting unit (For relay)
-
-
- UZ
UR
02
UW
32
32
Contact composition
Product
Product
Rated current
Product
Rated current
02 2NC
22 22AF 32 40AF 63 65AF 95 100AF
32AF 63 63AF 95 95AF
15
Control coil characteristics (3pole)
MC-9b 22AF MC-12b MC-18b MC-22b
40AF
65AF
MC-75a MC-85a MC-100a MD-60a MD-100a 100AF
Frame size
MC-32a MC-40a
MC-50a MC-65a MD-30a
Type
AC coil Control voltage
[Uc]
24, 32, 36, 42, 48, 80, 100, 110, 120, 220, 230, 240, 380, 400, 415, 440, 415, 440, 500, 550V 24, 48, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V 85~110%
50Hz 60Hz
[V] [V]
Voltage limit
[Uc]
Coil consumption at 20°C AC 220V Inrush
70
90
110
240
[VA] [VA]
9
9
13
17
60Hz
Holding
2.3
2.7
2.8
5.4
Heat dissipation
[W]
Operating time
15 ... 30
15 ... 30
15 ... 30
15 ... 30 10 ... 30
Closing
[ms] [ms]
4 ... 19
4 ... 19
4 ... 19
Opening
DC coil Control voltage
[Uc]
12, 20, 24, 30, 48, 60, 80, 100, 110, 125, 200, 220, 250V 85~110%
Voltage limit
[Uc]
Coil consumpton at 20°C DC 110V Inrush
6 6
9 9
9 9
18 18 75
[W] [W]
Holding
28
28
65
Time constant (L/R)
[ms]
Operating time
40 ... 60
50 ... 65
50 ... 65
100 ... 120
Closing
[ms] [ms]
4 ... 19
4 ... 19
4 ... 19
10 ... 25
Opening
Note) Either semi-electronic coil(A) or electronic coil(B) can be chosen for MC-130a and MC-150a.
Line
A1 A2
Load
Note) A1(A2) in line side is internally connected to A1(A2) in load side.
A1 A2
16
Contactors (22AF)
Description - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable
- AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available rating - 1NO1NC Auxiliary contact built-in as standard - UA-1 is available on only left side - Degree of protection: IP20
Rating
MC-12b
MC-18b
MC-22b
MC-9b
Contactor type
kW
A kW
A kW
A kW
A
AC duty
AC3
200/240V 2.5 380/440V 4 500/550V 4
11
3.5 5.5 7.5 7.5 2.2
13 12 12
4.5 7.5 7.5 7.5 3.7
18 18 13 16 11 32 18 18 13 18 18 18 12 9
5.5
22 22 20 18 18 13 45 20 20 15 20 20 20 20 15 20 20 15 8
9 7 6 8 6
11 15 15
690V
4
9
AC4
200/240V 1.5 380/440V 2.2
11
3.7 5.5
MC-22b
4
9
4
AC1
- - - - - - - - - - - - -
25 10 10
27 12 12 10 12 12 12 12
- - - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - - -
DC1 duty (L/R=1ms)
2-pole
24V
in series 48V
110V
6
3-pole
24V
10 10
in series 48V
110V
8 8 4 8 6 4
DC2,4 duty (L/R=15ms)
2-pole
24V
in series 48V
6 4
6 4
110V
2.5
3-pole
24V
12 10
12 10
in series 48V
110V
8
8
2pole for DC contact
Directly mountable overload relay Conductor size (solid, stranded)
MT-32
AWG
16~10 1.5~4
16~8
14~8
14~8
1.5~10
2.5~10
2.5~10
(the max. number of conducts: 2) mm² Conductor type
65/75°C Cu wire only
3pole for DC contact
Coil voltage*
Certification • CE(IEC) • UL508 • CCC
60Hz AC DC DC
24, 120, 208, 230, 240, 480V
24V
Note) Please be cautious for wiring control power cable, especially “ + ” (Positive) and “ - ” (Negative) polarity should be correctly considered.
* Coil voltages stocked in branch may vary. Multiple replacement voltages are available.
17
Contactors (40AF)
Description - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable
- AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available rating - 2NO2NC Auxiliary contact built-in is possible as standard - Degree of protection: IP20
Rating
MC-40a
MC-32a
Contactor type
kW
A
kW
A
7.5
32
11
40
AC3
200/240V 380/440V 500/550V
AC duty
15
32 28 20 17 20 17 55 25 25 25 25 25 25 25 20 10 25 25 20
18.5
40 32 23 17 25 24 60 35 35 25 35 35 35 35 20 10 35 30 20
18.5 18.5
22 22 22
690V
1000V
22
MC-40a
AC4
200/240V 380/440V
4.5 7.5
5.5
11
DC1 duty
AC1
- - - - - - - - - - - - -
- - - - - - - - - - - - -
2-pole
24V
(L/R=1ms)
in series 48V
110V
3-pole
24V
in series 48V
110V
DC2,4 duty (L/R=15ms)
2-pole
24V
in series 48V
110V
3-pole
24V
in series 48V
2pole for DC contact
110V
Directly mountable overload relay Conductor size (solid, stranded)
MT-32
AWG
12~8
8~6
2.5~10
10~16
(the max. number of conducts: 2) mm² Conductor type
65/75°C Cu wire only
3pole for DC contact
Coil voltage*
Certification • CE(IEC) • UL508 • CCC
60Hz AC
120, 208, 240, 480V
* Replacement coils are available in various voltages.
18
Contactors (65AF)
Description - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable - Both screw and Box terminal (lug) type are available - AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available rating - 2NO2NC Auxiliary contact built-in is possible as standard
- Degree of protection: IP20
Rating
MC-65a
MC-50a
Contactor type
kW
A
kW
A
15
55
18.5
65
AC3
200/240V 380/440V 500/550V
AC duty
22 30 30 30
50 43 28 23 35 32 50 40 35 50 50 50 45 25 15 50 35 30
30 33 33 30 11 22
65 60 35 23 50 47 50 40 35 65 65 65 45 25 15 50 35 30
690V
1000V
MC-65a
AC4
200/240V 380/440V
7.5
15
DC1 duty
AC1
- - - - - - - - - - - - -
100
- - - - - - - - - - - - -
115
2-pole
24V
(L/R=1ms)
in series 48V
110V
3-pole
24V
in series 48V
110V
DC2,4 duty (L/R=15ms)
2-pole
24V
in series 48V
110V
3-pole
24V
in series 48V
2pole for DC contact
110V
Directly mountable overload relay Conductor size (solid, stranded)
MT-63
AWG
10~4 6~25
8~3
10~35
(the max. number of conducts: 2) mm² Conductor type
65/75°C Cu wire only
3pole for DC contact
Coil voltage*
Certification • CE(IEC) • UL508 • CCC
60Hz AC
120, 208, 240, 480V
* Replacement coils are available in various voltages.
19
Contactors (100AF)
Description
- 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable - Both screw and Box terminal (lug) type are available - AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available rating - 2NO2NC Auxiliary contact built-in is possible as standard - Degree of protection: IP20
Rating
MC-85a
MC-100a
MC-75a
Contactor type
kW
A
kW
A
kW
A
55 30 55 45 37 19 37
105 105
22
75
25
85
AC duty
AC3
200/240V 380/440V 500/550V
37 37 37 37
75 64 42 28 55 52 75 65 50 75 75 75 65 40 20 80 60 50
45 45 45 37 15 30
85 75 45 28 65 62 80 65 50 80 80 80 65 40 20 80 60 50
85 65 28 80 75
690V
1000V
MC-100a
AC4
200/240V 13 380/440V 25
DC1 duty
- - - - - - - - - - - - -
160 100 100 80 100 100 100 100 60 40 100
AC1
- - - - - - - - - - - - -
125
- - - - - - - - - - - - -
135
2-pole
24V
(L/R=1ms)
in series 48V
110V
3-pole
24V
in series 48V
110V
DC2,4 duty (L/R=15ms)
2-pole
24V
in series 48V
110V
3-pole
24V
90 80
in series 48V
2pole for DC contact
110V
Directly mountable overload relay Conductor size (solid, stranded)
MT-95
8~00 10~70
AWG
8~2
8~0
10~35
10~50
(the max. number of conducts: 2) mm² Conductor type
65/75°C Cu wire only
3pole for DC contact
Coil voltage*
Certification • CE(IEC) • UL508 • CCC
60Hz AC DC DC
120, 208, 240, 480V
250V
* Replacement coils are available in various voltages.
20
Accessories
Parts to build reversing contactors are available for sizes MC-18a - MC-100a
Interlocks
Component parts for assembling by customer Interlock unit, UR-02 & Wire kit UW UR-02 ia a mechanical interlock unit and provides 2NC contacts for use in electrical interlocking.
Interlock unit
UW is used for making reversing circuit between two contactors.
Wire kit
Interlock unit
Aux Contact
Contactor
Pole
Type
Weight
Type
Weight
- - - -
UW-22 0.04kg UW-32 0.05kg UW-63 0.12kg UW-95 0.33kg
MC-9b~22b MC32a~40a
Wire kit
3P
UR-02 0.06kg
MC-50a, MC-65a
MC-75a~100a
Rating of the contacts in the interlocks Rated operation voltage
600V
Rated insulation voltage
1000V
Rated frequency
50/60Hz
Rated thermal current Rated operation current AC15 duty
16A
120V 240V 380V 480V 500V 600V 125V 250V
6A 3A
(A600)
1.9A 1.5A 1.4A 1.2A
DC13 duty
0.55A 0.27A
(Q300)
R/1/L1 S/3/L2 T/5/L3
R/1/L1 S/3/L2 T/5/L3
111NC
A1
A2
121NC
A1
A2
A1
A2
A2
112NC
A1
122NC
W/6/T3 V/4/T2 U/2/T1
W/6/T3 V/4/T2 U/2/T1
21
Accessories
Installation of Interlock and Wire kits
Click
1
2
1
Click
2
After installing interlock unit wiring kit can be assembled. Wiring kit contains two molded wires - one for line side and the other for load side. - In case of assembling reversing contactor, please check the R, S, T/U, V, W mark on the contactor and Wire kit.
And then install the other contactor on the other side of the interlock unit as shown.
Install the interlock unit on the side of a contactor first. Fit each part as indicated in the fig.
Surge unit
It absorbs the surge arisen out of the coil of the contactor. It can be installed simply to the contactor. - Rated operation voltage (Ue): AC 24 ~ 440V / DC 24 ~ 125V - Rated insulation voltage (Ui): 1000V - Rated impulse withstand voltage (Uimp): 8kV - Degree of protection: IP20 - Combination with 3Pole 6a/3~150a/3, 4Pole 32a/4~85a/4
US Type
US Type
Surge unit
Internal elements spec.
Rated voltage
Contactor
Type US-1 US-2 US-4
Composition
V
R
C
120V 270V 120V
100Ω 100Ω 100Ω
0.1µF 0.1µF
3Pole MC 6a~150a 9b~22b
Varistor+RC
24~48V
AC
Varistor+RC
100~125V
RC
DC
24~48V
0.47µF
22
Accessories
Replacement coils
To replace the existing coil to change voltage or repair.
Coil voltage
Contactor
AC coil
DC coil DC (V)
AC 60Hz (V)
AC 50/60Hz (V)
MC-9b MC-12b MC-18b MC-22b MC-32a MC-40a MC-50a MC-65a MC-75a MC-85a MC-100a
277
480
24
220 240
120
-
277
24 120 220 120 220
240 500
24
24
277
240 500
24
110 220
240 500
Replacement process
23
Overload relays
General descriptions
Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against overloads, phase failure, long starting times and prolonged stalling of the motor.
Four versions are available according to the protection function and trip class as below. 1. Non-differential: 3pole-2bimetal(heater) and trip class 10A 2. Non-differential: 3pole-3bimetal(heater) and trip class 10A 3. Differential: 3pole-3bimetal(heater) and trip class 10A 4. Differential: 3pole-3bimetal(heater) and trip class 20
Configuration of the front
Upstream connections
Relay type
Trip indicator Stop/Test button Reset button/Selector (manual or automatic reset) Auxiliary contacts(1NO+1NC)
Protection cover Adjustment dial Sealing the protection cover
Downstream connections
MT-32
MT-63
MT-95
24
Overload relay specifications
MT type Thermal Overload Relays
40AF
65AF 10A MT-63/3K�S/L Screw/Lug clamp Screw/Lug clamp Screw clamp 3 690V Up to 690V 6kV IP 20 -5~+40°C
100AF 10A MT-95/3K�S/L Screw/Lug clamp Screw/Lug clamp Screw clamp 3 690V Up to 690V 6kV IP 20 -5~+40°C
Frame size Trip class Type
10A MT-12/3K�S Screw clamp Screw clamp Screw clamp 3 690V Up to 690V 6kV IP 20 -5~+40°C
Differential type Main-upstream Main-downstream Auxiliary
Terminals
Number of poles Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse voltage (Uimp) Degree of protection (IEC 60 529) Temperature compensation (°C) Functions
■ ■ ■ ■ 0.1~40A
■ ■ ■ ■ 4~65A
■ ■ ■ ■ 7~100A
Trip indicating Stop Test Manual/Automatic Reset
Setting range(A) Nominal
Wire size
current rating
mm²
AWG
1~1.6 1.6~2.5 2.5~4
1.3 2.1 3.3 5 6.5 7.5 8.5 11
1
18
4~6 5~8 6~9
1~1.5
18~16
7~10 9~13 12~18 18~25 22~32 - - 28~40
1.5~2.5
16~14 14~12
15 19
2.5
2.5~4
12~10
21.5 27
4~6
10
30 34 42 54 65 74 83 90
4~10 6~10
10~8 10~8
28~40 34~50 45~65
10
8
54~75 63~85 70~95
16~25
6~4
25~35
4~3
MC-75a, 85a, 100a 80~100
MC-50a, 65a
MC-9b, 12b, 18b, 22b, 32a, 40a UZ-32
Applied contactors Separate mounting unit
UZ-63S/L
UZ-95S/L
Note : Screw clamp and Lug types are available for the main terminals of 65AF, 100AF and 150AF relays. The other AF relays provide Screw clamp types only.
②
①
① Main terminals/upstream ② Auxiliary terminals ③ Main terminals/downstream
③
25
Accessories for overload relays
Separate mounting units
These accessories are used to mount the relays separately from contactors. If a relay is combined with a unit, it can be mounted on DIN rail or panel by fixing screws.
Unit
Relay
Type
Weight
MT-32/2H� MT-32/2H� MT-32/2K� MT-32/2D� MT-63/2H� MT-63/2H� MT-63/2K� MT-63/2D� MT-95/2H� MT-95/3H� MT-95/3K� MT-95/3D�
UZ-32
68g
UZ-63S/L
134g
UZ-95S/L
230g
Remote reset units
These accessories are used to reset the relays on the panel door.
Cable length (L)
Type
UM-6R
600 mm
2. The bending radius of the flexible reset bar should not be less than 15mm.
55
35
R15
Ø10
Reset Bar
Bracket
Ø8 Door hole cutting
Panel door
26
Overload relay ordering types
Trip class 10A Terminal type: Screw Degree of protection: IP20 MT-32
Ordering type
Setting range
Separate
Contactor
(A)
mounting unit
Differential
1~1.6
MT-32/3K1.3 MT-32/3K2.1 MT-32/3K3.3 MT-32/3K5 MT-32/3K6.5 MT-32/3K7.5
1.6~2.5
2.5~4
MT-32/�
4~6 5~8 6~9
MC-9b MC-12b MC-18b MC-22b MC-32a MC-40a
UZ-32
7~10 9~13
-
MT-32/3K11 MT-32/3K15
12~18 16~22 18~25 22~32 28~40
-
MT-32/3K21.5 MT-32/3K27 MT-32/3K34
UZ-32(34A)
Trip class 10A Terminal type: Screw(S), Lug(L) Degree of protection: IP20 MT-63
Ordering type
Setting range
Separate
Contactor
(A)
mounting unit
Differential
28~40 34~50 45~65
MT-63/3K34S/L MT-63/3K34S/L MT-63/3K34S/L
MC-50a MC-65a
UZ-63S/L
MT-63/�S
MT-63/�L
MT-95
Ordering type
Setting range
Separate
Contactor
(A)
mounting unit
Differential
54~75 63~85 70~95 80~100
MT-95/3H65S/L MT-95/3H74S/L MT-95/3H83S/L MT-95/3H90S/l
MC-75a MC-85a MC-100a
UZ-95S/L
MT-95/�L
MT-95/�S
27
Reay for IE3
Frame size
22AF
40AF
Type AC-3
MC-9b MC-12b MC-18b MC-22b MC-32a MC-40a
200/240V kW 1.5
2
2.5
3
4.5
5.5
A 6
7.5 3.5
10 12.5 18
23 11 23 11 18 11
380/440V kW 2.2
5
6.5
9
A 5
7 4 7 4 5
10 12.5 18
500/550V kW 2.2
4.5
7.5
10
A 4
7.5 11.5 16
690V
kW 3
4 5
9
10
A 3.5
10 11.5 13
1000V
kW -
- -
- -
- -
11
11
A -
9.7
9.7
Frame size
65AF
100AF
Type AC-3
MC-50a MC-65a 9 37 18.5
MC-75a MC-85a
MC-100a
200/240V kW
7.5 31.5 15 28.5 15 24.5
11 43 22 43 27 37 22 24 20 16
15 49 25 49 30 43 25 26 20 16
18.5
A
60 30 60 35 49 30 37 20 16
380/440V kW
A
37 22 34 18.5
500/550V kW
A
690V
kW
15 16 16 13
A
20 16 13
1000V
kW
A
28
3-pole contactors dimensions (18AF/22AF)
[mm]
MC-6a~18a AC 1NO or 1NC
0.3kg
MC-6a~18a DC 1NO or 1NC
0.5kg
MC-9b~22b AC 1NO1NC
0.3kg
* ( ) MC-18b, 22b
MC-9b~22b DC 1NO1NC
0.5kg
29
3-pole contactors dimensions (40AF)
[mm]
MC-32a~40a AC
0.4kg
MC-32a~40a DC
0.6kg
MC-32a~40a AC
2NO2NC
0.5kg
MC-32a~40a DC
2NO2NC
0.8kg
30
3-pole contactors dimensions (65AF)
[mm]
MC-50a~65a AC
0.9kg
MC-50a~65a DC
1.2kg
MC-50a~65a AC 2NO2NC
1kg
MC-50a~65a DC 2NO2NC
1.3kg
31
3-pole contactors dimensions (100AF)
[mm]
MC-75a~100a AC
1.8kg
MC-75a~100a DC
2.7kg
MC-75a~100a AC 2NO2NC
1.9kg
MC-75a~100a DC 2NO2NC
2.8kg
32
Certifications
Type
Approvals
Certificates
Cerficate
-
IEC
UL
CSA
GB
IEC
KEPIC
Mark and name
CE U.S.A & cUL
CSA
CCC
KEMA
DEMKO
Type
Korea
Europe U.S.A & Canada Canada
China Netherlands Denmark
Korea
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
MC-6a MC-9a MC-12a MC-18a MC-9b MC-12b MC-18b MC-22b MC-32a MC-40a MC-50a MC-65a MC-75a MC-85a MC-100a MC-130a MC-150a MC-185a MC-225a MC-265a MC-330a MC-400a MC-500a MC-630a MC-800a MC-1260a MC-1400a MC-1700a MC-2100a MT-12/2H MT-32/2H MT-63/2H MT-95/2H MT-150/2H MT-225/2H MT-400/2H MT-800/2H MT-12/3H MT-32/3H MT-63/3H MT-95/3H MT-150/3H MT-225/3H MT-400/3H MT-800/3H MT-12/3K MT-32/3K MT-63/3K MT-95/3K MT-150/3K MT-225/3K MT-400/3K MT-800/3K MT-12/3D MT-32/3D MT-63/3D MT-95/3D MT-150/3D MT-225/3D MT-400/3D MT-800/3D
Metasol Contactors
● ● ● ● ● ● ●
●
Thermal Overload Relays Nondifferential (2-heater) Thermal Overload Relays Nondifferential (3-heater)
● ● ●
● ● ●
● ● ●
● ● ●
Thermal Overload Relays Differential
● ● ●
● ● ●
Thermal Overload Relays Class 20
Note) ● : Completion
33
Notes
34
Echo Automation & Control Specialists Greg Donahoe 712.890.5553 greg.donahoe@echoautomation.com Stacy Michaelsen 402.476.3281 stacy.michaelsen@echoautomation.com
712.322.0291 4325 Gifford Rd. Council Bluffs, IA
402.330.9995 14326 C Cir. Omaha, NE
402.476.3281 3600 N 25th St. Lincoln, NE
Echo LSIS Control V1.0 02/2020