Echo Electric Motors
Reference Motor Nameplate Data & Informa on
Nameplate data is the first cri cal step in determining motor replacement. Much of the informa on needed can generally be obtained from the nameplate. Record all nameplate informa on; it can save me and confusion.
MARINE DUTY IEEE45 USCG
E
EEV102077
MODEL AN 256THFNA9026ABL
MTG. F1
FRAME 256T
PART NO TYPE TFS ENCL TEFC
SER.
INS CL
MAX AMB
DES. B
PH 3
F
DUTY CONT
40 ° C
RISE 65 ° C
IP 56
IC 41
CODE G
MTH/YR MFG. 12/2003 ALTITUDE 1000M/3300 FT
WT/LBS 412
WT/KG 187
E49747
SHAFT END BRG
6309
6210
OPP
HZ 60
VOLTS 460
HZ 50
VOLTS 400
IEEE841
HP 20
KW 15
HP 15
KW 11
F.L. AMPS 24.1 PF(COS) φ 84.0
SF 1.25
F.L. AMPS 21.5 PF(COS) φ 82.0
SF 1.15
RPM 1775
RPM 1475
NOM EFF 93.0 SHAFT END BEARING 45BC03XPP30X
NOM EFF 93.0 OPP. END BEARING 50BC02XPP30X
LR21839
API RP14F
FOR USE ON PWM VFD 10:1 VT, 20:1 CT, 1.0 SF. CSA CERTIFIED FOR CLASS I, GROUP A, B, C, D, DIV. 2/ZONE 2 GROUP IIA, IIB, IIC; TEMPERATURE CODE T3 @ 1.0SF OR T2B @ 1.15SF ON SINE-WAVE POWER, OR T2D @ 1.0SF ON PWM TYPE VFD POWER.
CC003A
Important Nameplate Data ▪ MODEL - The ID number DATE CODE - The month and year manufactured ▪ MTG. - Moun ng ▪ SER. - Serial number ▪ TYPE - Electrical type ▪ DES. - Code by NEMA or IEC ▪ PH - Electrical phase (usually 1 or 3) ▪ INS CL - Insula on class ▪ DUTY - Time ra ng under load ▪ MAX AMB - The allowable surrounding air temperature ▪ ENCL - Enclosure, Example: TEFC ▪ RISE - The temperature rise over ambient expressed in degrees ▪ Celsius when the motor operates at nameplated HP or KW ▪ IP - Inherent Protec on of the enclosure to solids and liquids ▪ FRAME - The size and moun ng ▪ PART NO. - Customer part number ▪
Important Nameplate Data ▪ MTH/YR MFG. - Month and year motor was manufactured
WT/LBS - Motor weight in pounds ▪ WT/KG - Motor weight in kilograms ▪
HZ - Input frequency of the power supply (usually 50 or 60 HZ) ▪ VOLTS - Voltage ra ng of the motor at the opera ng frequency ▪ HP - Rated horsepower the motor will produce ▪ KW - Rated output in wa s ▪ F.L. AMPS - The rated load current expressed in amps at nameplate ▪ horsepower with nameplate voltage and frequency ▪ S.F. - Percentage of the rated horsepower the motor can safely ▪ operate at, Example: 1.15 SF (115% of rated HP) ▪ PF / COS - Power Factor / Cosine is the ra o of actual power to ▪ the apparent power ▪ RPM - Full load speed at rated frequency ▪ NOM EFF - Average Efficiency ▪ SHAFT END BEARING - Manufacturer drive end bearing number ▪ OPP. END BEARING - Manufacturer opposite drive end bearing number ▪ SHAFT END BRG - Drive end bearing size ▪ OPP - Opposite drive end bearing size ▪
as defined by IEC 34-5 ▪ IC - Inherent Cooling ▪ CODE - NEMA locked-rotor KVA ▪
©2013 Regal Beloit Corpora on. BROCHURE SB800 7572M/BH/10-13/1K/QG
EchoGroupInc.com
149